Noise curves specify the acoustic ambient noise in an indoor environment. Typical disturbing noises are the background noise caused by an air conditioning system as well as noises from heating or ventilation systems (HVAC).
Background noise that is annoying creates fatigue and can negatively affect productivity and safety. Too much noise also affects the ability to communicate, thus the intelligibility of speech. Therefore, standard methodologies for quantifying such noise have been developed. Different rooms, locations, regulations and applications may allow individual acceptable noise ratings. In most cases, the goal is that background noise should not interfere with the purpose of the room, e.g. the noise of an office air-conditioning system should not interfere with telephone calls or conversations.
The XL2 Acoustic Analyzer measures the background noise spectrum of the unoccupied room in accordance with the standard. The resulting frequency spectrum gets classified by the Noise Curves. The noise rating is designated as the value of the lowest noise curve not “touched” by the measured noise spectrum in 1 dB steps.
This allows a quick verification if the background noise in the room under test meets the specified requirements and shall not annoy people occupying the room. The Noise Curve functionality is optional and requires that the Spectral Limits Option be installed on the instrument.
The XL2 indicates the frequency band with the highest noise curve rating between 16 Hz and 8 kHz. Additionally, the instrument calculates also the speech interference level (SIL) result by averaging the octave-band sound pressure levels at 500 Hz, 1000 Hz, 2000 Hz and 4000 Hz.
The XL2 Acoustic Analyzer measures the following Noise Curves:
Room Acoustics Reporter offers a dedicated solution for generating standardized noise curve reports. The software calculates the average background noise spectrum in the room. This may be compared with the target range – based on the usage of the room. The software supports data recorded by the measurement function Spectrum (RTA) as well as the specific XL2 functions Noise Curves, 1/12 Octave and Cinema Meter.
Room Acoustics Reporter supports the following Noise Curve standards:
including
Yes. With the STIPA Option installed, the XL3 or XL2 measure speech intelligibility according to IEC 60268-16:2020 (and also support older editions), including features like ambient noise correction and automated averaging.